Maintaining Event Linkages for Notifications

Objective

After completing this lesson, you will be able to Maintain the event linkages for Quality Notifications.

Maintain Event Linkages for Quality Notifications

This process allows users to maintain the created or changed event linkages for Quality Notifications.

Step 1: Navigate to the New Entries: Details of Added Entries screen

To do this, complete the following steps:

  1. Run transaction code SPRO.
  2. Choose SAP Reference IMG.
  3. Navigate to Integration with Other SAP ComponentsManaged Gateway for Spend&Network for BuyerSAP Business Network IntegrationApplication Specific SettingsApplication Specific SettingsSAP Ariba Supply Chain CollaborationQuality Notification.
  4. Choose Maintain Event Linkage for Quality Notification.
  5. Choose New Entries.

Step 2: Maintain Created Event Linkages

To maintain the created event linkages for quality notifications, enter the following data and choose Save.

FieldValue
Object CategoryBOR Object Type
Object TypeBUS2078
EventCREATED
Receiver TypeCREATED_AN
Receiver CallFunction Module
Receiver Function ModuleARBCIG_EXT_EVENT_NOTIF_CRATED
Check Function ModuleARBCIG_EXT_EVENT_CRT_CHECK
Linkage ActivatedSelect the checkbox
Behavior Upon Error FeedbackSystem defaults
Receiver StatusNo errors

Step 3: Maintain Changed Event Linkages

To maintain the changed event linkages for quality notifications, enter the following data and choose Save.

FieldValue
Object CategoryBOR Object Type
Object TypeBUS2078
EventDATACHANGED
Receiver TypeDATACHANGED_AN
Receiver CallFunction Module
Receiver Function ModuleARBCIG_EXT_EVENT_NOTIF_CHANGED
Check Function ModuleARBCIG_EXT_EVENT_CHG_CHECK
Linkage ActivatedSelect the checkbox
Behavior Upon Error FeedbackSystem defaults
Receiver StatusNo errors